After connection it did not have the light on the module, therefore checked the power on B2 with the ground A1 read 0 volts. Ran a new ground restored power to module and van started. Make sure to check incoming power to module pink wire B2 and black wire A1 ground. Therefore in my case I had a bad ground coming into the GM security module connector C1 pin A1 black wire, wich caused the module to act like there is a security problem shutting off the fuel injectors.